FLA-T series
temperature integrated

One of three wires of this strain gauge is made of copper-nickel alloy, while other two wires are made of ordinary copper. A T-type thermocouple is composed by a copper-nickel wire and a copper wire. Strain measurement by quarter bridge 3-wire method and temperature measurement by thermocouple are possible with one strain gauge. This gauge must be measured by TML data loggers.

Main Test Materials Metal Materials Backing Epoxy
Operating Temperature -20 to +80°C Materials Element Cu-Ni alloy foil
T-thermocouple
Compensation range +10 to +80°C Strain limit 3%
(30000×10-6)
Bonding adhesive CN,P-2 Fatigue life at room temp. 1×106
(±1500×10-6)

  • Single element(G.F. 2.1 approx.)
  • 0.08mm2 PVC lead wire pre-attached
    Total resistance of lead wire per meter:0.44(Ω)(as for copper wire)

     

  • Bridge circuit
  • Type Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance
    (Ω)
    Lead wires length
    FLA-1T-11-3LT
    FLA-1T-17-3LT
    FLA-1T-23-3LT
    1 1.3 5 2.5 120 3-wire 3m
    FLA-2T-11-3LT
    FLA-2T-17-3LT
    FLA-2T-23-3LT
    2 1.5 6.5 3 120 3-wire 3m
    FLA-5T-11-3LT
    FLA-5T-17-3LT
    FLA-5T-23-3LT
    5
    1.5
    10
    3
    120
    3-wire 3m

    Temperature integrated gauges are available for other series of strain gauges.
    Contact Feteris Components for details.

    we made this!